New house, 1940s, natural gas fireplace insert. The pilot light makes a high pitch hiss.

Sometimes it doesn’t, for moments, but mostly it does it all the time.

In this video I’ve turned the knob back past pilot and towards off, I can make it stop.

Is this dangerous?

  • seathru@quokk.au
    link
    fedilink
    English
    arrow-up
    8
    ·
    8 days ago

    A lot of times this can just be from dust buildup on/around that nozzle (I’m almost sure that’s not the proper terminology tho). An easy thing to try is shutting off the gas to the insert and taking a can of compressed air to that nozzle and everything around it. If you can easily take off the panel in front of it, even better, spray all the dust out you can.

    Is this dangerous?

    The hissing noise is not. Turning your pilot knob to some in-between setting is.

    • hereiamagain@sh.itjust.worksOP
      link
      fedilink
      arrow-up
      2
      ·
      6 days ago

      That did the trick! Cleaning it out. It was extremely full of crap, and now the flame is bigger and no more hissing. Though the whole flame is louder now, in the lower frequencies.

      Not gonna mess with it though.

    • bigfish@lemmy.dbzer0.com
      link
      fedilink
      arrow-up
      6
      ·
      8 days ago

      I’ll add, as I just fixed this at my parent’s house, if you get it opened up, an old toothbrush to scrub the end of the pilot gas line helps here too. Just be careful not to move the sparker.

      • hereiamagain@sh.itjust.worksOP
        link
        fedilink
        arrow-up
        1
        ·
        6 days ago

        I took a toothbrush to it, and it was unbelievable how much crap came out of that pilot housing. Tremendous. The flame is bigger and bluer now. Ironically, while the hissing has gone away, the audible volume of the rest of the flame, mostly the lower frequencies, has gotten louder.

        All in all I think is much better than it was.

  • Vicinus@piefed.zip
    link
    fedilink
    English
    arrow-up
    5
    ·
    8 days ago

    I know nothing about the systems in question, but it seems the “hiss” is in time with the flame changing shape. So, perhaps a blower or valve turning on/off, open/closing.

    Again, I know nothing, but if it’s a sound from the equipment turning on/off, I don’t think it would be potentially hazardous. Probably very annoying though.

    • hereiamagain@sh.itjust.worksOP
      link
      fedilink
      arrow-up
      3
      ·
      8 days ago

      I was twisting the valve ever so slightly to demonstrate that the noise can come and go with the pilot still lit.

      But yes, the flame was changing shape slightly when it was doing it by itself earlier, so something is definitely happening.

      Others say dust up in the nozzle, which makes sense it sat unused for awhile

  • tyler@programming.dev
    link
    fedilink
    arrow-up
    4
    ·
    8 days ago

    Is it a thermopile millivolt system? I just fixed mine last week and when it was hissing it was because I lit the pilot with the grub screw too wide open. There’s a tiny little brass screw that is right next to the pilot control knob that allows you to adjust the pilot flame size to get the right coverage on the thermopile.

    Of course it could also be dust.

    • hereiamagain@sh.itjust.worksOP
      link
      fedilink
      arrow-up
      2
      ·
      edit-2
      6 days ago

      So I cleaned it out and that seems to have solved the hissing problem. It was QUITE full of crap.

      Ironically though, the pilot is louder than before, just instead of hissing, it’s a lower frequency “small torch” sound.

      Looking at it, there’s a copper capillary tube going from the flame sensor to the valve, so I’m almost certain this is a mercury vapor thermovalve.

      Edit: I ended up turning it down a bit. At first until there was no sound at all, but that was obviously too low.

      So I turned it up until it was engulfing the bulb, but not splitting the flame on it. You can hear it, but it’s not a blowtorch anymore.

        • hereiamagain@sh.itjust.worksOP
          link
          fedilink
          arrow-up
          1
          ·
          6 days ago

          Yep! I think it’s running good now.

          Definitely confusing until you start playing with it and seeing what works and doesn’t work.

          • tyler@programming.dev
            link
            fedilink
            arrow-up
            1
            ·
            5 days ago

            Haha none of it made sense for me. I had to resort to going to a heating forum and got the help I needed there after a day or two of talking back and forth!

    • hereiamagain@sh.itjust.worksOP
      link
      fedilink
      arrow-up
      3
      ·
      8 days ago

      Thanks for the picture! And the explanation! I wouldn’t have thought of this.

      After looking it up, I’m sure this must be a thermopile system. That or mercury vapor maybe?

      I shut it off last night to cool down, but by time I remembered to check if it was cool enough to install the logs and start looking closely, it was bedtime. I won’t have time today or tonight, busy day ahead, but I will report back when I do!

      I’ll dust it first to be sure, but I think you’re right, it might need turned down a tiny bit. Thank you!